Added an additional optical sensor named FW_LOW inside my 75-gallon RO/DI storage tank to turn off the ATK if the water level is too low. Upon contact with liquid this sensor will communicate to your Apex to send an alert or trigger other actions. Ive found these values work really well on my Radions to look like moonlight: Click the gear icon above your lights output, Click the Advanced (gear icon) at the top right. Just like the manual Feed Cycle buttons, but all unattended! If Tmp > 78.2 Then OFF Announcing the BRAND NEW Orphek Atlantik iCon! NjZlYjQyNGRmZTFjYmQxN2IwY2JkMWIzMTA5MjQ3NTMwZWZkMjNlODJkNGFj Any input with alarms configured will show a checkmark in the Alarms column: Click the input to get to its configuration settings where you can change the specified limits: If you want to remove the alarm, click the Alarm dropdown and select Never: There may be situations where you want the Apex to take an action based on the amount of power a device is consuming. Added a virtual output named Maintenance to disable the ATK while Im conducting maintenance. NDkwNDYzNjQ0YjY4MjMzM2YwOGEzN2IwY2VmMjhkYTljMzJhMzg4NGZkYjIx If Float1 Open Then ON However, in this next example the water temperature is still 77.9 F, but there is an additional condition to be evaluated: In this example, we have a virtual output named Maintenance that we turned on while performing routine maintenance on the tank. You are limited to 12 characters, and the name must be unique within your list of outputs, inputs, and module names. However, instead of getting a repeated alert every hour, the When command on the virtual output turns the output OFF after 10 minutes, which cancels the Email_Alert. Defer 120:00 Then ON, Set OFF Please enter your email address below to receive a password reset link. Neptune Apex Optical Water Sensor Setup and Review Reefing Ain't Easy 1.03K subscribers Subscribe 51 Share Save 4.8K views 2 years ago In this video I explain how to set up and use the OS-1. Again, the most common example of Min Time is for the ATO pump. FeedD Feeding fish with Auto Feeder. If you ever slide it to OFF, you will not receive any alarms you programmed, If you slide it to ON, it will just send you a notification right away regardless of your programming. For example, if a heater has the following programming, and the water temperature is 77.9 F, heres how the Apex will decide what to do: In this example, the Apex turns on the heater output because the last line that evaluated as True was the first line. Just that single line of If Output Maintenance = ON Then OFF is all thats needed. While Neptunes documentation walks you through the ATK setup, they dont really provide a lot of information about the resulting programming created by the Fusion ATK Setup task. Its one of the most important reasons for using a controller. -----END REPORT-----. After dumping frozen water bottles into your tank, youll also eventually notice that your skimmer is also full even though you didn't get a notification about it. $52.00 + $5.85 shipping . Ensure your FMM module is correctly identifying the optical sensors. If Temp > 99 Then ON Want to grow your business and reach a wider audience? Earn 10,830 Reward Points. When the Apex has an active alarm condition, it can send a notification via email, SMS text message, or directly to the Fusion App on a smartphone or tablet. Frustrating and a LOT of email/text warnings. Doing that now and I'm sure there will be issues given Neptune's sparse instructions. Included are a fastening nut and silicone washer. If Output Alert_FUG_Hi = ON Then ON Keep it coming!Sent from my iPhone using Tapatalk, Tuesday's topic --ATK Programming and Troubleshooting. How can I wire the klir motor to apex? YWQ4NmZkYzMzMjFhMjk5Y2YyMTQ1ZjZmZmY3ZTE3MWY0ZWMwNDNmNGQwOGU5 It seems to cycle over a 30-40 minute period. I think there maybe room for the sensor. This is considered an AND comparison. The 120v outlets on the EB832 can be referenced in programming to read the watts or amps value: As an example, I have a small cheap powerhead in my sump to create flow where my 2-part dosing tubes feed into the water. If FeedB 000 Then 1, Fallback OFF The basic operation of the ATK is to tell the PMUP (Practical Multi-purpose Utility Pumponly Neptune would create an acronym that spelled backwards describes the actual device). I use a virtual output named Alert_ATO to keep track of this for me: Then in my Email_Alarm output, I added this line: If you recall from the ATK Troubleshooting tutorial, the lower optical sensor in my sump is named ATK_LO, and when it reports OPEN then the ATK_PMUP output is turned on to refill the sump. If FeedB 000 Then OFF My favorite example is a warning if my ATO hasnt run recently. ODdkY2NlOTEzMTUxMzZmM2FkN2RmOTYxMmY1NzFhM2JkODRiYWMzZWY4NGY1 Hopefully this will get you started with creating some convenient automation for your setup. Helpful, direct, and easy to apply information for anyone in needing to learn how to use there Apex ATK. Creating an ocean in your living room and keeping it alive for years to come is a complex task and it takes a community with different skills to come together to support each other. Instead, use a folded up paper towel or a thick piece of cloth between the probe and the concrete. The next step is to create a lighting profile. ZjNmMjg3MjVkZjE2Mjg5MzRlMzQ2NGExNjg4N2UwMzg1YTM1YjEwMTZmZjNk and Neptune are different colors by NOIRLab Amanda Kocz. If Output vFeed = ON Then ON The state of an output is not changed until all lines of programming are evaluated. Ensure your optical sensor plugs are firmly seated in the FMM sockets. You cannot specify the same value for the start and end times, so 10:00 to 10:00 is invalid. In your Apex alert programming, add this as the final condition so it doesn't get overridden by any other alert conditions: Since some devices may not be controlled by your Apex and just plugged into normal power strips, you should think through which items you want to run on battery power and which ones are safe to be off during a power outage. It would be better to change the sequence to: Now when you receive the alarm about the Temp > 99, youll run out of the theater and head right home. The Neptune Systems Apex Lunar Simulator Module (LSM) can be used with anyNeptune Systems Apex LSM Lunar LED Strings. Only 2 more topics to go, and you don't have to wait 8 weeks to see them here! I also have the klir but due to sump design the optic sensor will not work. New . Heres how I use mine: This is accomplished by adding the following line to each output youd like off during the Feed Cycle: For example, the powerheads are turned off with this code: For the skimmer, I need it to wait for the sump water level to return to normal after the return pump has been off. One of the major limitations with alarm programming is that only the last line that turns the output On is the line of text youll receive in the notification. Defer is particularly useful when basing an output on the reading of a probe or sensor. The When command is very unique in Apex programming. However, with my 30+ year career in IT systems and my love of all things automation, I realized I could leverage my technical background and the Apex to automate most functions on the aquarium. Defer 000:04 Then OFF Instead, use a low-profile leak probe, lift the edge of the carpet and padding a bit and slip the probe underneath. Once the Email_Alert output is on, it will send text and email messages once per hour until the situation is corrected or the output is manually turned off. Pretty slick! Click the Update Settings button to save the new name to the Apex. This allows you to review its operation later, or to remotely check in on its activity. Here are some examples: The EmailAlm output itself behaves exactly like any other outlet and follows the same logic that Ive covered in earlier tutorial topics. The Klir motor goes thru a 12 volt wall wart into a controller that monitors the sensor. Cant believe these articles dont have more likes. We Also Recommend I/O Breakout Box $4495 0.25" Flow Sensor $2095 0.5" Flow Sensor $3195 1" Flow Sensor $6295 Apex Controller Kits Neptune Systems Lighting Neptune Systems Pumps Apex Modules Apex Probes Neptune Systems LLS Liquid Level Sensor Starting at $44.95 In stock Add to Cart Neptune Systems MOS Magnetic Optical Sensor $39.95 In stock Add to Cart Neptune Systems LD-3 Optical Multi-Surface Leak Sensor $39.95 In stock Add to Cart If Output EB_3_Skimmer = OFF Then OFF, If Time HH:MM to HH:MM Then [ON/OFF/Profile], Set OFF Below are links to buy them.0:00 Intro2:18 Price3:25 How to set it up9:16 My Review of the product12:09 Want me to figure out a cheaper option?Sensor alone:https://www.bulkreefsupply.com/os-1-optical-level-sensor-neptune-systems.htmlSensor with Magnet:https://www.bulkreefsupply.com/os-1m-optical-level-sensor-with-mount-neptune-systems.htmlFMM Module:https://www.bulkreefsupply.com/fmm-fluid-monitoring-module-neptune-systems.html When you first connect your FMM you will have five new tiles on your Apex Fusion Dashboard. Before getting into the programming steps, there are some prerequisites needed for power monitoring to work: Once these steps are done, you can configure various outlets on your Energy Barto react when your house power goes out. This should cause the pump to turn off: If both the lower sensor and the upper sensor both fail, the float valve will pinch the tubing to stop the water flow: While this should prevent a flood in your house, it will not turn off the pump since this is a simple mechanical valve and does not communicate with the Apex. It also ignores the optical sensor at night when Im sleeping with an If Time command: Then in my alarm programming, I just check the status of the virtual output: Now I dont need to worry about low 2-part waking me up at 3am, and during the day if its low it will only send me one notification instead of nagging every hour. The included documentation was minimal, Neptunes online documentation was a bit scattered and disjointed, and the programming language was different than all the widely used standards I was familiar with. If you want to use If Time for a shorter duration, it would need to be combined with the Defer statement: This will cause it to wait until 10:01 to turn on, then turn off at 10:02. effectively giving you a 1 minute timer: Ill explain Defer in more detail in the next section. I just tried setting Defer to 000:00and got this error: This tutorial will cover several aspects of power monitoring in an Apex environment: *Note: These topics do not apply to older Apex units or older Energy Bars. The third line disables the Swabbie from running if my skimmer is off. Purchase this Apex 12V auxiliary power adapter: Plug your Apex Energy Bar into your UPS (Uninterruptible Power Supply)battery backup. Click the Apex menu at the top, then click Misc, Select Day of New Moon from the Setup dropdown. Lets say you want to run a circulation pump once per day for an hour every day except on Saturday when you are doing maintenance: Remember from my introduction section that the last line of programming that evaluates True will dictate what the output does. Lowered the Min Time command timer from 60 minutes down to 30 minutes. The problem is defining what is normal. Min Time 030:00 Then OFF, If Output output_name [Amps/Watts] [] Then [ON/OFF], Fallback OFF Ill let you know when I get it. If Output Alert_FW_LO = ON Then ON The probe is weighted so that it sets flat on any solid horizontal surface. If you want the Apex to send you alerts when the power is out, you will also need your Internet router connected to a battery backup. For each month, enter the day of the new moon. The FMM (Fluid Monitoring Module) is a multi-purpose device that, with the help of various accessories, enables your Apex to do: With the various flow monitoring sensors you can monitor the flow inside the pipes of your return pump, emergency drains, reactor pumps, RODI feed, and much more. Neptune Apex Monitoring Use This InfluxDB Integration for Free The Apex System is an aquarium controller that allows you to monitor your aquarium to maximize your aquarium's success and long-term health. Set OFF Your leak detection probes need to be tied to an alarm outlet in order to be notified if there was an alert. Add the same statements for each connected leak detection probe as you did for the email alarm output. Once we turn off the Maintenance output, the Apex will turn the heater on because only the first condition is True. You should have already configured your email address and/or cellular phone number in your Fusion Notifications. Please refer to the APEX Fusion Get Started guide if you have not yet set up notifications. MWRkYWI3YTgxOWI1YTdlN2FjZTc3YjVkMjZiYzdjNjVjNzQwNDRlNDQzNGMw Lowered the When command timer from five (5) minutes down to three (3) minutes. If Float1 Open Then ON I always recommend enabling the Log checkbox so youll have a record of any time the output was turned on or off. ZjMzZWQxNzhhNDY1YWU0ZjRhYWYxOThmOTA2MWJmYWQwNzQzNTkwYjFhZTI2 YTgyNmU1ZWZkZTRiNjgwMzgxZTZkNmRhZmEzZGQ0MmMxYTE1MGZhMTgwYTI0 ZTQ3ZTZkN2VmZTkyMzU2YTRiYmRhNjAwOTNhYTJkMGRmM2U3NGIxNWRiYmVh Great question. Earn 23,085 Reward Points, Earn 1,239 Reward Points $16.99 . NDAzYjJjZWE4MGVjOWQzNjI4Y2RlOTEyNmY0OWQ3N2Y3OWU4MjE1MTlmY2U3 Earn 4,485 Reward Points, Earn 899 Reward Points I can see the wattage vary in what looks like steps. Defer statements can be placed anywhere in the list of programming lines because they apply to the output itself and are not part of what evaluates as True or False. Included are a fastening nut and silicone washer. Go into the FMM module settings, click Configure, then confirm outlets 1 and 2 are both detected as Optical Sensors: Wipe off your optical sensors if they are dirty. So while we didnt see any coral spawning, we did see a solar eclipse!). You really need to push them hard until they "click" into place. The Apex has built-in schedules for lunar cycles. Click the orange cloud (Update) button when done. Instead, I use a virtual output named vMoonthat combines the If Moon command with an If Time command: This allows moon lighting to run any time the moon is visible, except during my normal lighting schedule from 7am to 9pm. Neptune FMM for ATO | Marine and Reef General Discussion | MARSH New posts Search forums Welcome back Guest! Remember to place that line below any line of code that may turn the device on because the code is processed from top to bottom, as covered in our Introduction tutorial. Apex supports custom lighting profiles for Radions and Vega/Hydra LED lights. MzgyMDc5OWFmMDJlMjY3YWFjMGQyOGUwMTM3ZjBiN2FhMWVjNjlmMDE2NDNk For a better experience, please enable JavaScript in your browser before proceeding. If FeedA 000 Then 1 OTg1OWU1N2NhNzliMzM2NGQ1MTVkZjZhNmNjMmJlOTkzNjU4ZGY3ZjIxMTMw But I'm sure I could pimp out my programming a bit more on existing items! If Output EB_7_SMPFLO Amps > 5.0 Then OFF It is used to switch an outputs tile from AUTO to OFF if a condition is met. If it doesn't move any water, verify the 24v power adapter is firmly plugged in to the FMM and that it has power. Select the FMM being used for the LDK if you have more than one FMM connected to your Apex system, Send the updated configuration to the Apex. Go into the FMM module settings, click Configure, then confirm outputs 1 and 2 are both detected as Optical Sensors. I'll flag this thread to come back to when I need some programming. Earn 7,185 Reward Points, Earn 1,189 Reward Points Defer 000:10 Then ON, Set OFF I have 2 magnetic floats via the BoB acting as high and. After accessing the Classic Dashboard, go to Configuration->Probe/Input setup, select the desired input from the drop-down menu, then rename it. Make sure the PMUP output tile is set to AUTO on your dashboard. The ATK (Automatic Top-off Kit) is Neptunes integrated ATO solution for Apex environments. You can configure the timers for each in the Misc Setup page: How you use the Feed Cycles is up to you. 1. Here are some examples: In general, you should only run the bare minimum devices on battery power. At visible wavelengths Neptune has a distinctly bluer color whereas Uranus is a pale shade of cyan. FMK Flow Monitoring Kit - Neptune Systems, FMM Fluid Monitoring Module - Neptune Systems, OS-1 Optical Level Sensor V2 - Neptune Systems, OS-1-M Optical Level Sensor V2 With Mount - Neptune Systems, ATK V2 Auto Top Off Kit - Neptune Systems, Small CO2 Scrubber (1.1lb Capacity) - IceCap, Medium CO2 Scrubber (2.2lb Capacity) - IceCap, DOS & DDR Dosing System Package - Neptune Systems, A3 Apex Pro Controller System with Extra Energy Bar 832 - Neptune Systems, A3 Apex Controller System with Extra Energy Bar 832 - Neptune Systems, Trident & A3 Apex Pro Controller System Bundle - Neptune Systems, Trident & A3 Apex Controller System Bundle - Neptune Systems, A3 Apex Controller System - Neptune Systems, LD-3 Optical Multi-Surface Leak Sensor - Neptune Systems, MOS Magnetic Optical Sensor - Neptune Systems, A3 Apex Jr Controller System - Neptune Systems, A3 Apex Pro Controller System - Neptune Systems, A6 DC 200 Protein Skimmer - Adaptive Reef, A8 DC 300 Protein Skimmer - Adaptive Reef. Earn 3,360 Reward Points, Earn 479 Reward Points Question: Can you set the value for defer to "zero" for testing purposes or do you need to have a minimum value (one second) or delete the line altogether?

Imprudent Crossword Clue 13 Letters, Articles N